The magnetic tunnel junctions (MTJs)-based sensors (TMR sensor) are promising magnetic field sensor because of room temperature operation, small device size, and the low power consumption. Since the TMR sensors with such features are considered to be widely applicable not only to the magnetic recording, the TMR sensors will be a key device in the ICT and IoT societies. In addition, because of the dramatic increase in sensitivity of TMR sensors in recent years, the realization of the device that can detect the weak magnetic field of pico-Tesla such as bio-magnetic field is expected. Magnetoencephalography (MEG) has been applied to brain function research and diagnosis of brain diseases, but unfortunately, the conventional measurement method using a SQUID sensor cannot measure brain field by touching the scalp, the head must be fixed, and maintenance costs are high. The TMR sensors operating at room temperature have the potential to solve these problems. In addition, it has the great advantage that it does not require a special magnetic shielded room, and in principle, it allows measurement while the subject is moving. In addition to bio-magnetic field measurements, the possibility of realizing nuclear magnetic resonance image (MRI) measurements using the same TMR sensor under the low magnetic dc field, such as earth field, is expected. There are various techniques for imaging the shape of a body, such as MRI, ultrasonic waves, blood flow, etc., but techniques for measuring the image of the activity and shape of a body with the same sensor devices have not been reported. We have already reported on the measurement of cardiac magnetic field (magnetocardiography: MCG) and MEG using TMR sensors 1, but, the further improvement in sensitivity and detectivity of TMR sensors is required to realize the actual TMR based-MCG, -MEG and -MRI equipment. We present recent progress in the development of highly sensitive TMR sensors.
We have achieved the lowest magnetic field detectivity of 1.0 pT / Hz0.5 at 1 Hz in the TMR sensor using a magnetic flux concentrator (MFC) (Fig. 1). By using a TMR sensor with high magnetic field resolution in the low frequency region, we succeeded in measuring MCG at real-time and MEG with a small number of averaging times. Further, as shown in Fig. 1, the developed TMR sensor has an extremely low magnetic field detectivity of 0.1 pT / Hz0.5 or less in the kHz band. Protons in the human body generate nuclear magnetic resonance (NMR) at a frequency of 1 to 3 kHz under a weak magnetic field of μT, and we succeeded in measuring the NMR signal for the first time using the TMR sensor (Fig. 2). These results show that the MEG signal and the MRI using NMR can be simultaneously measured by the same TMR sensor device.
This work was partly supported by JST S-innovation project, the Center for Innovative Integrated Electronic Systems (CIES), the Center for Science and Innovation in Spintronics (CSIS), and the Center for Spintronics Research Network (CSRN).

Frequency dependence of detectivity in developed TMR sensors with/without magnetic flux concentrator (MFC)

Proton NMR signals under low magnetic field of 50 μT measured by developed TMR sensors with MFC

Downloads

Transcript English (automatic)

Next from 2022 Joint MMM-INTERMAG

Reactive Molecular Dynamic Simulation of Plasma Etching Process of L10-FePt HAMR Media in Embedded Mask Patterning
technical paper

Reactive Molecular Dynamic Simulation of Plasma Etching Process of L10-FePt HAMR Media in Embedded Mask Patterning

2022 Joint MMM-INTERMAG

Jianxin Zhu
Jianxin Zhu and 1 other author

11 January 2022

Similar lecture

Multi-TMR device with a compact footprint for low magnetic field detection at room temperature
poster

Multi-TMR device with a compact footprint for low magnetic field detection at room temperature

2022 Joint MMM-INTERMAG

+1
Susana Cardoso de Freitas and 3 other authors

10 January 2021

Stay up to date with the latest Underline news!

Select topic of interest (you can select more than one)

PRESENTATIONS

  • All Presentations
  • For Librarians
  • Resource Center
  • Free Trial
Underline Science, Inc.
1216 Broadway, 2nd Floor, New York, NY 10001, USA

© 2026 Underline - All rights reserved

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.